Summary of Important Safety Information - IntraLase® FS and iFS® Laser Systems

LASIK can only be performed by a trained ophthalmologist and for specified reduction or elimination of myopia, hyperopia, and astigmatism as indicated within the product labeling. Laser refractive surgery is contraindicated for patients: a) with collagen vascular, autoimmune, or immunodeficiency diseases; b) who are pregnant or nursing women; c) with signs of keratoconus or abnormal corneal topography; d) who are taking one or both of the following medications: Isotretinoin (Accutane®) and Amiodarone hydrochloride (Cordarone®). Potential side effects to LASIK may include dry eye, halos, glare, as well as other visual anomalies. LASIK requires the use of a keratome that cuts a flap on the surface of the cornea and may potentially cause inflammation, corneal scratch, epithelial ingrowth, and flap-related complications. Consult the Professional Use Information booklet for a complete listing of contraindications and risk information. Results may vary for each individual patient.

Caution: U.S. Federal law restricts these devices to sale, distribution, and use by or on the order of a licensed eye care practitioner.

The IntraLase® FS and iFS® Laser Systems are ophthalmic surgical lasers indicated for use in patients undergoing surgery or treatment requiring the initial lamellar resection of the cornea, in the creation of a lamellar cut/resection of the cornea for lamellar IntraLase-Enabled Keratoplasty (IEK), in the creation of a penetrating cut/incision for penetrating IEK, penetrating and intrastromal arcuate incisions (iFS® Laser Only) and for corneal harvesting. Initial lamellar resection contraindications may include cornea edema, glaucoma, and keratoconus. Initial lamellar resection risks and complications may include corneal pain, flap tearing, and epithelial ingrowth. IEK contraindications may include any corneal opacity adequately dense to obscure visualization of this iris, descemetocele with impending corneal rupture, previous corneal incisions that might provide a potential space into which the gas produced by the procedure can escape, and cornea thickness requirements that are beyond the range of the system. Patients are requested to consult with their eye care professional for a complete listing of the contraindications and risks. U.S. Federal Law restricts this device to sale, distribution, and use by or on the order of a physician or other licensed eye care professional.

The product may contain mercury. Please dispose accordingly to state, local or federal laws.

Important Safety Information - IntraLase® FS and iFS® Laser Systems

VISX Wavefront-guided LASIK for Correction of Myopic, Hyperopic, and Mixed Astigmatism (CustomVue LASIK Laser Treatment)

Statements regarding the potential benefits of wavefront-guided LASIK (CustomVue) are based upon the results of clinical trials. These results are indicative of not only the CustomVue Treatment but also the care of the clinical physicians, the control of the surgical environment by those physicians, the clinical trials' treatment parameters and the clinical trials' patient inclusion and exclusion criteria. Although many clinical trial patients after the CustomVue Procedure saw 20/20 or better and/or had or reported having better vision during the day and at night, compared to their vision with glasses or contact lenses before the procedure, individual results may vary. You can find information about the clinical trials below and in the Professional Use Information Manuals for the VISX STAR S4 Excimer Laser System and WaveScan WaveFront System (CustomVue Treatments).

As with any surgical procedure, there are risks associated with the CustomVue Treatment. Before treating patients with the CustomVue Procedure, you should carefully review the Professional Use Information Manual, complete the Physician CustomVue Certification Course, provide your patients with the Patient Information Booklet for CustomVue LASIK Laser Treatment, and discuss the risks associated with this procedure and questions about the procedure with your patients.

WAVEFRONT-GUIDED LASIK INDICATIONS AND INTENDED USES:
The VISX STAR S4 Excimer Laser System and WaveScan WaveFront System are approved to perform wavefront-guided laser assisted in-situ keratomileusis (LASIK) treatments for the reduction or elimination of low to moderate myopic astigmatism up to -6.00 D MRSE, with cylinder between 0.00 and -3.00 D in patients 21 years of age or older; and in patients with documented evidence of a change in manifest refraction of no more than 0.50 D (in both cylinder and sphere components) for at least one year prior to the date of pre-operative examination.

Wavefront-guided LASIK for correction of low to moderate myopic astigmatism is an elective procedure with the alternatives including but not limited to eyeglasses, contact lenses, photorefractive keratectomy (PRK), conventional LASIK, and other refractive surgeries. Approval of the low to moderate myopic astigmatism application is based on a clinical trial of 351 eyes (189 primary and 162 secondary). Of all eyes treated, 318 were evaluated for effectiveness with 98.8% accountability at 3 months, 277 eyes with 96.9% accountability at 6 months, 102 eyes with 95.3% accountability at 9 months, and 86 eyes with 95.6% accountability at 12 months. The studies found that of the 277 eyes eligible for the uncorrected visual acuity (UCVA) analysis of effectiveness at 6 months, 100% were corrected to 20/40 or better, and 95.8% were corrected to 20/20 or better in 71 spherical myopia eyes; and 99.5% were corrected to 20/40 or better, and 93.2% were corrected to 20/20 or better in 206 astigmatic myopia eyes. The study showed that at the 3 month stability time point: there was a loss of ?2 lines of best corrected vision that can be obtained with spectacles in 1 of 239 astigmatic myopia eyes and there was no loss of ?2 lines of best corrected vision in 79 spherical myopia eyes; there was 1 of 239 astigmatic myopia eyes with best spectacle corrected visual acuity (BSCVA) worse than 20/25 and none in 79 spherical myopia eyes with BSCVA worse than 20/25. During the course of study, no eye lost >2 lines of BSCVA and no eye had a BSCVA worse than 20/40.

The VISX STAR S4 IR Excimer Laser System with VSS Technology and WaveScan WaveFront System are approved to perform wavefront-guided laser assisted in-situ keratomileusis (LASIK) treatments for the reduction or elimination of high myopic astigmatism from -6.00 D to -11.00 D MRSE, with cylinder between 0.00 and -3.00 D in patients 21 years of age or older; and in patients with documented evidence of a change in manifest refraction of no more than 1.00 D (in both cylinder and sphere components) for at least one year prior to the date of pre-operative examination.

Wavefront-guided LASIK for correction of high myopic astigmatism is an elective procedure with the alternatives including but not limited to eyeglasses, contact lenses, photorefractive keratectomy (PRK), conventional LASIK, and other refractive surgeries. Approval of the application is based on a clinical trial of 184 eyes. Of all eyes treated, 180 were evaluated for effectiveness with 97.8% accountability at 3 months, 178 eyes with 96.7% accountability at 6 months, 170 eyes with 96.5% accountability at 9 months, and 107 eyes with 93.9% accountability at 12 months. The studies found that of the 178 eyes eligible for the uncorrected visual acuity (UCVA) analysis of effectiveness at 6 months, 98.3% were corrected to 20/40 or better, 97.2% were corrected to 20/32 or better, and 84.3% were corrected to 20/20 or better without spectacles or contact lenses. The study showed that of 83 spherical and 101 astigmatic eyes, no eyes lost 2 or more lines of best corrected vision that can be obtained with spectacles (BSCVA) and none of the eyes had BSCVA worse than 20/40.

The VISX STAR S4 Excimer Laser System and WaveScan WaveFront System are approved to perform wavefront-guided laser assisted in-situ keratomileusis (LASIK) treatments for the reduction or elimination of hyperopic astigmatism up to 3.00 D MRSE, with cylinder between 0.00 and 2.00 D in patients 21 years of age or older; and in patients with documented evidence of a change in manifest refraction of no more than 1.00 D (in both cylinder and sphere components) for at least one year prior to the date of pre-operative examination.

Wavefront-guided LASIK for the correction of hyperopic astigmatism is an elective procedure with the alternatives including but not limited to eyeglasses, contact lenses, photorefractive keratectomy (PRK), conventional LASIK, and other refractive surgeries. Approval of the hyperopic astigmatism application is based on a clinical trial of 144 eyes (74 primary and 70 secondary). Of all eyes treated, 134 were evaluated for effectiveness with 98.5% accountability at 3 months, 131 eyes with 97.0% accountability at 6 months, 118 eyes with 90.8% accountability at 9 months, and 27 eyes with 87.1% accountability at 12 months. The studies found that of the 131 eyes eligible for the uncorrected visual acuity (UCVA) analysis of effectiveness at 6 months, 97.3% were corrected to 20/40 or better, and 66.2% were corrected to 20/20 or better in 74 spherical hyperopia eyes; and 93.0% were corrected to 20/40 or better, and 56.1% were corrected to 20/20 or better in 57 astigmatic hyperopia eyes. The study showed that at the 6 month stability time point: there was no loss of ?2 lines of best corrected vision that can be obtained with spectacles in either 63 astigmatic hyperopia eyes or 74 spherical hyperopia eyes; none of the 63 astigmatic hyperopia eyes or 74 spherical hyperopia eyes had best spectacle corrected visual acuity (BSCVA) worse than 20/25. During the course of study, one of 63 eyes with astigmatic hyperopia lost >2 lines of BSCVA at 1 month, no eyes with spherical hyperopia lost >2 lines of BSCVA, and no eye had a BSCVA worse than 20/40.

The VISX STAR S4 IR Excimer Laser System with VSS Technology and WaveScan WaveFront System are approved to perform wavefront-guided laser assisted in-situ keratomileusis (LASIK) treatments for the reduction or elimination of naturally occurring mixed astigmatism when the magnitude of cylinder (from 1.0 to 5.0 D) is greater than the magnitude of sphere and the cylinder and sphere have opposite signs; in patients 21 years of age or older; and in patients with documented evidence of a change in manifest refraction of no more than 0.50 D (in both cylinder and sphere components) for at least one year prior to the date of pre-operative examination.

Wavefront-guided LASIK for the correction of mixed astigmatism is an elective procedure with the alternatives including but not limited to eyeglasses, contact lenses, photorefractive keratectomy (PRK), conventional LASIK, and other refractive surgeries. Approval of the mixed astigmatism application is based on a clinical trial of 86 eyes. Of all eyes treated, 86 were evaluated for effectiveness with 100.0% accountability at 3 months, 80 eyes with 95.2% accountability at 6 months, 69 eyes with 86.3% accountability at 9 months, and 63 eyes with 94.0% accountability at 12 months. The studies found that of the 86 eyes eligible for the uncorrected visual acuity (UCVA) analysis of effectiveness at 3 months, 95.3% were corrected to 20/40 or better, 91.9% were corrected to 20/32 or better, and 61.6% were corrected to 20/20 or better without spectacles or contact lenses. The study showed that of 86 astigmatic eyes, one eye temporarily lost 2 lines of best corrected vision that can be obtained with spectacles at 1 month and at 6 months and none of the eyes had best spectacle corrected visual acuity (BSCVA) worse than 20/40.

CONTRAINDICATIONS:
Wavefront-guided LASIK is contraindicated in patients with collagen vascular, autoimmune or immunodeficiency disease, signs of keratoconus or abnormal corneal topography, patients taking Isotretinoin (Accutane) or Amiodarone hydrochloride (Cordarone) or are pregnant or nursing.

WARNINGS:
Wavefront-guided LASIK is not recommended in patients who have diabetes, a history of Herpes simplex or Herpes zoster keratitis, significant dry eye that is unresponsive to treatment, or severe allergies. For the treatment of low to moderate myopic astigmatism, lower uncorrected visual acuity may be anticipated in the treatment of higher degrees of myopia with and without astigmatism (?5.0 D MRSE).

PRECAUTIONS:
The safety and effectiveness of wavefront-guided LASIK surgery has ONLY been established with an optical zone of 6 mm and an ablation zone of 8 mm for myopic astigmatism, and an optical zone of 6 mm and an ablation zone of 9 mm for hyperopic and mixed astigmatism. Long-term risks of wavefront-guided LASIK beyond 12 months have not been studied. The safety and effectiveness of the STAR S4 IR Excimer Laser System have NOT been established for wavefront-guided treatment of low to moderate myopic astigmatism in patients: whose WaveScan WaveFront diameter is less than 6 mm, for treatments greater than 6 diopters of MRSE or with greater than 3 diopters of astigmatism and for retreatment with CustomVue LASIK. The safety and effectiveness of the STAR S4 IR Excimer Laser System have NOT been established for wavefront-guided treatment of high myopic astigmatism in patients: whose WaveScan WaveFront diameter is less than 5 mm, for treatments greater than -11 diopters of MRSE or with greater than 3 diopters of astigmatism. The safety and effectiveness of the STAR S4 IR Excimer Laser System have NOT been established for wavefront-guided treatment of hyperopic astigmatism in patients: whose WaveScan WaveFront diameter is less than 5 mm; for treatments greater than 3 diopters of MRSE or with greater than 2 diopters of astigmatism and for retreatment with CustomVue LASIK. The safety and effectiveness of the STAR S4 IR Excimer Laser System have NOT been established for wavefront-guided treatment of mixed astigmatism in patients: whose WaveScan WaveFront diameter is less than 5 mm, for treatments greater than 5 diopters or less than 1 diopter of astigmatism and for retreatment with CustomVue LASIK.

Although the WaveScan WaveFront System measures the refractive error and wavefront aberrations of the human eyes, including myopia, hyperopia, astigmatism, coma, spherical aberration, trefoil, and other higher-order aberrations through sixth order, in the clinical studies for low to moderate myopic astigmatism, hyperopic astigmatism and mixed astigmatism, the average higher-order aberration did not decrease after CustomVue Treatment. In the clinical studies for high myopic astigmatism, the average higher-order aberration increased after CustomVue Treatment.

It is possible, after wavefront-guided LASIK treatment, that patients will find it more difficult than usual to see in conditions such as very dim light, rain, snow, fog, or glare from bright lights at night. Visual performance possibly could be worsened by large pupil sizes or decentered pupils. Pupil size should be evaluated under mesopic illumination conditions.

The use of Percentage Nomogram Adjustment should be based upon careful consideration of patient and surgeon information, in addition to environmental conditions surrounding the surgery. The simultaneous use of the Percentage Nomogram Adjustment and the Physician Adjustment has not been studied in controlled investigations, and should not be attempted until the accuracy of the Nomogram setting has been verified for the same laser, treatment conditions and type of treatment. Therefore, the combined simultaneous use of the Percentage Nomogram Adjustment and the Physician Adjustment is not recommended without careful analysis of post-operative refractive results.

ADVERSE EVENTS AND COMPLICATIONS:
The clinical trial for low to moderate myopic astigmatism showed that the following adverse events or complications occurred in at least 1% of the 351 eyes at any interval up to 6 months post-treatment: inflammation of the cornea under the flap (1.4%); double or ghost images (1.4%); and scratch on the surface of the eye (1.4%). The following subjective symptoms frequency rated "often or always" were increased in the effectiveness cohort at 6 months post-treatment on 258 eyes compared with pre-treatment on 332 eyes: dryness (9% vs. 6%); fluctuation of vision (3% vs. 2%); glare (4% vs. 2%) and halos (7% vs. 5%).

The clinical trial for high myopic astigmatism showed that the following adverse events or complications occurred in at least 1% of the 184 eyes at one or more post-operative examinations up to 6 months post-treatment: epithelium in the interface (1.1%); peripheral corneal epithelial defect at 1 month or later (2.2%); corneal edema between 1 week and 1 month post-operatively (2.7%) and double vision (or "ghost images") in the operative eye (6.0%). The following subjective symptoms were reported as present "often or always" by a higher percentage of subjects 6 months after treatment than before treatment: dryness (10.8% vs. 9.3%); halos (21.6% vs. 15.4%); and ghosting or shadowing of images (2.8% vs. 1.1%).

The clinical trial for hyperopic astigmatism showed that the following adverse events or complications occurred in at least 1% of the 144 eyes at any interval up to 6 months post-treatment: cells growing under the flap (2.1%); feeling of something in the eye (1.4%); double or ghost images (11.3%); and scratch on the surface of the eye (2.1%). The following subjective symptoms rated "often or always" were increased in the effectiveness cohort at 6 months post-treatment on 131 eyes compared with pre-treatment on 136 eyes: dryness (17% vs. 6%); blurry vision (10% vs. 7%); fluctuation of vision (14% vs. 6%); halos (10% vs. 5%); double or ghost images (7% vs. 3%).

The clinical trial for mixed astigmatism showed that the following adverse events or complications occurred in at least 1% of the 86 eyes at one or more post-operative examinations up to 3 months post-treatment: miscreated flap (1.2%); cells growing under the flap (4.7%); and double vision (or "ghost images") in the operative eye (8.1%). The following subjective symptoms were reported as present "often or always" by a higher percentage of subjects 3 months after treatment than before treatment: dryness (22% vs. 6%); halos (20% vs. 13%).

The IntraLase® FS and iFS® Laser Systems are ophthalmic surgical lasers indicated for use in patients undergoing surgery or treatment requiring the initial lamellar resection of the cornea, in the creation of a lamellar cut/resection of the cornea for lamellar IntraLase-Enabled Keratoplasty (IEK), in the creation of a penetrating cut/incision for penetrating IEK, penetrating and intrastromal arcuate incisions (iFS® Laser Only) and for corneal harvesting. Initial lamellar resection contraindications may include cornea edema, glaucoma, and keratoconus. Initial lamellar resection risks and complications may include corneal pain, flap tearing, and epithelial ingrowth. IEK contraindications may include any corneal opacity adequately dense to obscure visualization of this iris, descemetocele with impending corneal rupture, previous corneal incisions that might provide a potential space into which the gas produced by the procedure can escape, and cornea thickness requirements that are beyond the range of the system. Patients are requested to consult with their eye care professional for a complete listing of the contraindications and risks. U.S. Federal Law restricts this device to sale, distribution, and use by or on the order of a physician or other licensed eye care professional.

The product may contain mercury. Please dispose accordingly to state, local or federal laws.

iFS<sup>®</sup> Advanced Femtosecond Laser

All of our femtosecond expertise culminates in our 5th-generation iFS® Laser. The iFS® Laser gives surgeons greater control for maximum customization — providing an indispensible tool for LASIK and beyond. With over 5 million procedures performed to date, IntraLase® Technology is the femtosecond technology of choice.

Flap Architecture Innovations

The iFS® Laser brings two major innovations in flap architecture: the inverted bevel-in side cut and elliptical-shaped flaps. When combined with a faster repetition rate and tighter spot/line separation, our 5th-generation iFS® Laser is a versatile tool that preserves corneal innervation and allows post-operative healing by creating a biomechanically stable corneal flap.

  • Inverted bevel-in side cut up to 150° for improved biomechanical stability1
  • Elliptical flap option to maximize stromal bed exposure
  • Tighter spot separation provides smoother stromal beds and a virtually effortless flap lift2
  • Lower energy per pulse, which may reduce tissue response and inflammation

Greater Biomechanical Stability and Faster Visual Recovery

The iFS® Laser provides the ideal combination of advantages: minimal disruption of corneal architecture, stronger flaps, fewer possible complications plus faster visual recovery.1

Customized Corneal Capabilities

The iFS® Laser brings advanced corneal options within reach, including intrastromal ring implantation and channels*, as well as IntraLase®-Enabled Keratoplasty. With the iFS® Laser, surgeons have the ability to create accurate, reproducible incisions in an almost limitless range of shapes and patterns.

*Channels used for inlays are CE marked only and are not available in the USA.

 

IntraLase-Enabled Keratoplasty

IntraLase® Technology is the first in the world used to create innovative-shaped corneal incisions for full-thickness corneal transplants.

  • Precisely shaped angled edges fit snugly to improve alignment6
  • Provides a smooth corneal contour with greater surface area to speed wound healing6

Information for consumers

For consumer information on iLASIK® please visit

ilasik.com
http://www.ilasik.com

Information for healthcare professionals

For more information on the iLASIK® Technology Suite and the iFS® Laser, please visit www.amo-ilasik.com

ilasik.com

Education, Practice Development & Customer Service resources

References

  1. Knorz MC, Vossmerbaeumer U. Comparison of flap adhesion strength using the AMADEUS microkeratome and the IntraLase® iFS® femtosecond laser in rabbits. J Refract Surg. 2008;24(9):875-878.
  2. Binder PS. AMO’s new iFS® advanced femtosecond laser: faster, safer, more versatile. Refractive Eyecare. 2008.
  3. Binder PS, Gray B, Brownell M, et al. Morphology of femtosecond intrastromal arcuate incisions. 2012.03.07-ME4839. 
  4. Meltendorf C, Burbach GJ, Ohrloff C, et al. Intrastromal keratotomy with femtosecond laser avoids profibrotic TGF-ß1 induction. Invest Ophthalmol Vis Sci. 2009;50(8):3688-3695.
  5. Rashid ER, Waring GO 3rd. Complications of radial and transverse keratotomy. Surv Ophthalmol. 1989;34(2):73-106. 
  6. Steinert RF. Using IntraLase® to improve penetrating keratoplasty. Refractive Eyecare. Feb 2007.

Summary of Important Safety Information - IntraLase® FS and iFS® Laser Systems

LASIK can only be performed by a trained ophthalmologist and for specified reduction or elimination of myopia, hyperopia, and astigmatism as indicated within the product labeling. Laser refractive surgery is contraindicated for patients: a) with collagen vascular, autoimmune, or immunodeficiency diseases; b) who are pregnant or nursing women; c) with signs of keratoconus or abnormal corneal topography; d) who are taking one or both of the following medications: Isotretinoin (Accutane®) and Amiodarone hydrochloride (Cordarone®). Potential side effects to LASIK may include dry eye, halos, glare, as well as other visual anomalies. LASIK requires the use of a keratome that cuts a flap on the surface of the cornea and may potentially cause inflammation, corneal scratch, epithelial ingrowth, and flap-related complications. Consult the Professional Use Information booklet for a complete listing of contraindications and risk information. Results may vary for each individual patient.

Caution: U.S. Federal law restricts these devices to sale, distribution, and use by or on the order of a licensed eye care practitioner.

The IntraLase® FS and iFS® Laser Systems are ophthalmic surgical lasers indicated for use in patients undergoing surgery or treatment requiring the initial lamellar resection of the cornea, in the creation of a lamellar cut/resection of the cornea for lamellar IntraLase-Enabled Keratoplasty (IEK), in the creation of a penetrating cut/incision for penetrating IEK, penetrating and intrastromal arcuate incisions (iFS® Laser Only) and for corneal harvesting. Initial lamellar resection contraindications may include cornea edema, glaucoma, and keratoconus. Initial lamellar resection risks and complications may include corneal pain, flap tearing, and epithelial ingrowth. IEK contraindications may include any corneal opacity adequately dense to obscure visualization of this iris, descemetocele with impending corneal rupture, previous corneal incisions that might provide a potential space into which the gas produced by the procedure can escape, and cornea thickness requirements that are beyond the range of the system. Patients are requested to consult with their eye care professional for a complete listing of the contraindications and risks. U.S. Federal Law restricts this device to sale, distribution, and use by or on the order of a physician or other licensed eye care professional.

The product may contain mercury. Please dispose accordingly to state, local or federal laws.